Case Report
BibTex RIS Cite

Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report

Year 2019, Volume: 10 Issue: 2, 58 - 60, 01.04.2019
https://doi.org/10.33706/jemcr.551140

Abstract

Introduction: The pseudo-tumor cerebri (PTC) is defined as the idiopathic
or benign intracranial hypertension (IH), complaints of which cannot be
explained in a different way. PTC is an exclusion diagnosis, in which the
neuroophtalmopathology of IH cannot be determined. The patients with PTC may
have complaints such as headache, nausea, vomiting, temporary blurred vision, and
mild-level vision loss or unilateral or bilateral abducens nerve paralysis may develop.
The radiological examination of patients yields normal results. In case that IH
develops due to any reason, the enlargement is seen in optic nerve sheath
diameter (ONSD) in the acute period.



Case
reports:
14 year-old patient,
who has been diagnosed for PTC in our unit, optic nerve sheath diameter (ONSD)
measurement and follow-up of pressure change of whom have been performed by using
ultrasonography (USG) method, is presented in order to discuss the contribution
of this non-invasive method to diagnosis, treatment, and observation processes.



Conclusion: USG and ONSD
measurement in PTC cases may be effective and reliable monitoring method as
much as invasive methods.

References

  • 1. Bekerman I, Sigal T, Kimiagar I, Almer ZE, Vaiman M. Diagnostic value of the optic nerve sheath diameter in pseudotumor cerebri. Journal of Clinical Neuroscience 2016; 30: 106-9.
  • 2. Salahuddin N, Mohamed A, Alharbi N, Ansari H, Khaled JZ, Marashly Q, et al. The incidence of increased ICP in ICU patients with non-traumatic coma as diagnosed by ONSD and CT: a prospective cohort study. BMC Anesthesiol. 2016; 16: 106.
  • 3. Friedmann DI, Jacobson DM. Diagnosis criteria for idiopathic intracranial hypertension. Neurology 2002; 59(95): 1492-5.
  • 4. Lochner P, Nardone R, Tezzeon F, Coppo L. Optic Nerve Sonography to Monitor Treatment Efficacy in Idiopathic Intracranial Hypertension: A Case Report. Journal of Neuroimaging 2013; 23: 533-4.
  • 5. Singleton J, Dagan A, Edlow JA, Hoffmann B. Real-time optic nerve sheath diameter reduction measured with bedside ultrasound after therapeutic lumbar puncture in a patient with idiopathic intracranial hypertension. American Journal of Emergency Medicine 2015; 33: 860.e5-7.
Year 2019, Volume: 10 Issue: 2, 58 - 60, 01.04.2019
https://doi.org/10.33706/jemcr.551140

Abstract

References

  • 1. Bekerman I, Sigal T, Kimiagar I, Almer ZE, Vaiman M. Diagnostic value of the optic nerve sheath diameter in pseudotumor cerebri. Journal of Clinical Neuroscience 2016; 30: 106-9.
  • 2. Salahuddin N, Mohamed A, Alharbi N, Ansari H, Khaled JZ, Marashly Q, et al. The incidence of increased ICP in ICU patients with non-traumatic coma as diagnosed by ONSD and CT: a prospective cohort study. BMC Anesthesiol. 2016; 16: 106.
  • 3. Friedmann DI, Jacobson DM. Diagnosis criteria for idiopathic intracranial hypertension. Neurology 2002; 59(95): 1492-5.
  • 4. Lochner P, Nardone R, Tezzeon F, Coppo L. Optic Nerve Sonography to Monitor Treatment Efficacy in Idiopathic Intracranial Hypertension: A Case Report. Journal of Neuroimaging 2013; 23: 533-4.
  • 5. Singleton J, Dagan A, Edlow JA, Hoffmann B. Real-time optic nerve sheath diameter reduction measured with bedside ultrasound after therapeutic lumbar puncture in a patient with idiopathic intracranial hypertension. American Journal of Emergency Medicine 2015; 33: 860.e5-7.
There are 5 citations in total.

Details

Primary Language English
Journal Section Case Report
Authors

Ozlem Talu Kendir

Hayri Levent Yılmaz This is me

Seyda Beğen Doğankoc This is me

Sevcan Bilen

Sinem Sarı Gokay This is me

Mihriban Ozlem Herguner This is me

Publication Date April 1, 2019
Submission Date September 8, 2018
Published in Issue Year 2019 Volume: 10 Issue: 2

Cite

APA Talu Kendir, O., Yılmaz, H. L., Doğankoc, S. B., Bilen, S., et al. (2019). Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report. Journal of Emergency Medicine Case Reports, 10(2), 58-60. https://doi.org/10.33706/jemcr.551140
AMA Talu Kendir O, Yılmaz HL, Doğankoc SB, Bilen S, Sarı Gokay S, Herguner MO. Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report. Journal of Emergency Medicine Case Reports. April 2019;10(2):58-60. doi:10.33706/jemcr.551140
Chicago Talu Kendir, Ozlem, Hayri Levent Yılmaz, Seyda Beğen Doğankoc, Sevcan Bilen, Sinem Sarı Gokay, and Mihriban Ozlem Herguner. “Measuring the Optic Nerve Sheath Diameter by Using Ultrasonography in Diagnosis and Follow-up of Pseudo-Tumor Cerebri: A Case Report”. Journal of Emergency Medicine Case Reports 10, no. 2 (April 2019): 58-60. https://doi.org/10.33706/jemcr.551140.
EndNote Talu Kendir O, Yılmaz HL, Doğankoc SB, Bilen S, Sarı Gokay S, Herguner MO (April 1, 2019) Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report. Journal of Emergency Medicine Case Reports 10 2 58–60.
IEEE O. Talu Kendir, H. L. Yılmaz, S. B. Doğankoc, S. Bilen, S. Sarı Gokay, and M. O. Herguner, “Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report”, Journal of Emergency Medicine Case Reports, vol. 10, no. 2, pp. 58–60, 2019, doi: 10.33706/jemcr.551140.
ISNAD Talu Kendir, Ozlem et al. “Measuring the Optic Nerve Sheath Diameter by Using Ultrasonography in Diagnosis and Follow-up of Pseudo-Tumor Cerebri: A Case Report”. Journal of Emergency Medicine Case Reports 10/2 (April 2019), 58-60. https://doi.org/10.33706/jemcr.551140.
JAMA Talu Kendir O, Yılmaz HL, Doğankoc SB, Bilen S, Sarı Gokay S, Herguner MO. Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report. Journal of Emergency Medicine Case Reports. 2019;10:58–60.
MLA Talu Kendir, Ozlem et al. “Measuring the Optic Nerve Sheath Diameter by Using Ultrasonography in Diagnosis and Follow-up of Pseudo-Tumor Cerebri: A Case Report”. Journal of Emergency Medicine Case Reports, vol. 10, no. 2, 2019, pp. 58-60, doi:10.33706/jemcr.551140.
Vancouver Talu Kendir O, Yılmaz HL, Doğankoc SB, Bilen S, Sarı Gokay S, Herguner MO. Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report. Journal of Emergency Medicine Case Reports. 2019;10(2):58-60.