Particle Size Detection By Bioimpedance Needle Probe
Abstract
Objectives: The aim of this study was to test the Bioimpedance probe needle on in-vitro tissue phantom. Study Design: Bioimpedance probe needle that was connected to a bioimpedance measurement device to record spectra in the kHz range. The probe consists of an 18Gauge 1.2x89 mm spinal needle. The probe was used for obtaining impedance information about the polystyrene microspheres which were in different diameters; 1, 2 and 4 micrometers. The current was transferred to the phantom and conductivity information was obtained by the probe. Results: Bioimpedance probe needle allows the discrimination of different particle sizes based on their specific signatures. The sensitivity of the probe to particle size in tissue phantom was tested during the study. Spectroscopic data were evaluated with resistance values at 50 kHz and the information about the particle size in the tissue phantom was obtained. Bioimpedance spectra results which were obtained from polystyrene microspheres showed that the resistance values were increasing while the size of the particle was enlarging. Conclusion: Due to the highly accurate differentiation of particle size in the tissue phantom, our probe has the potential to be used in the rapid detection of Escherichia coli or Acinetobacter baumannii which have different sized microorganisms in the tapped cerebrospinal fluid without being cultured in real time. In addition, it is possible for the probe to perform cell counting and differentiation in cell culture studies.
Keywords
References
- Hodgkin AL, Huxley AF. A quantitative description of membrane current and its application to conduction and excitation in nerve. The Journal of physiology. 1952;117:500-44. [CrossRef]
- Schwan HP. Electrical properties of tissue and cell suspensions. Adv Biol Med Phys. 1957;5:147-209.
- Lukaski HC. Biological indexes considered in the derivation of the bioelectrical impedance analysis. The American journal of clinical nutrition. 1996;64(3 Suppl):397S-404S. [CrossRef]
- Selberg O, Selberg D. Norms and correlates of bioimpedance phase angle in healthy human subjects, hospitalized patients, and patients with liver cirrhosis. European journal of applied physiology. 2002;86:509-16. [CrossRef]
- Rigaud B, Hamzaoui L, Frikha MR, Chauveau N, Morucci JP. In vitro tissue characterization and modelling using electrical impedance measurements in the 100 Hz-10 MHz frequency range. Physiol Meas. 1995;16(3 Suppl A):A15-28.
- Suselbeck T, Thielecke H, Weinschenk I, Reininger-Mack A, Stieglitz T, Metz J, et al. In vivo intravascular electric impedance spectroscopy using a new catheter with integrated microelectrodes. Basic Res Cardiol. 2005;100:28-34. [CrossRef]
- Brown BH, Tidy JA, Boston K, Blackett AD, Smallwood RH, Sharp F. Relation between tissue structure and imposed electrical current flow in cervical neoplasia. Lancet. 2000;355:892-5. [CrossRef]
- Farre R, Blondeau K, Clement D, Vicario M, Cardozo L, Vieth M, et al. Evaluation of oesophageal mucosa integrity by the intraluminal impedance technique. Gut. 2011;60:885-92. [CrossRef]
Details
Primary Language
Turkish
Subjects
-
Journal Section
-
Authors
Tuba Denkçeken
Publication Date
June 1, 2020
Submission Date
-
Acceptance Date
-
Published in Issue
Year 1970 Number: 2